Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2014 Nov ; 62 (11): 1102
Article in English | IMSEAR | ID: sea-155804
2.
Article in English | IMSEAR | ID: sea-140041

ABSTRACT

The burning problem that all the implantologists are confronted today is the complications and failures occurring with the treatment of osseointegrated implants. To further optimize the treatment outcome, etiologies and factors associated with implant failures should be elucidated. Conceivably such knowledge is needed for developing adequate treatment and prevention strategies. Hence, this paper is intended to provide an insight regarding various aspects of failures that affect dental implants.


Subject(s)
Causality , Dental Implantation , Dental Implantation, Endosseous , Dental Implants/statistics & numerical data , Dental Restoration Failure , Humans
3.
Article in English | IMSEAR | ID: sea-139806

ABSTRACT

Aim: This study aims to analyze the stress patterns and displacement in the cantilever resin bonded fixed partial denture (RBFPD) and compare it with the conventional cantilever fixed partial denture using 3-D finite element analysis. Also, the effect of cement on the displacement and stress patterns in conventional cantilever fixed partial denture was to be analyzed. Materials and Methods: Three-dimensional models were prepared layer wise to depict the conventional cantilever and the cantilever RBFPD. Once the models were made, the material properties were assigned and divided into three groups. (2-conventional cantilever with resin cement, 1- conventional cantilever with GIC cement and 3-resin bonded cantilever with resin cement). Load was applied in vertical as well as lateral directions and the stress patterns along with displacement were analyzed. Results: The results revealed that the von Mises stresses in all the three groups were found to be almost equal under vertical loading. Under lateral loading, the stress was more in cantilever RBFPD. Displacement in all the three axes was significantly less in the cantilever RBFPD. Conclusion: Stress concentration in the lateral direction in cantilever RBFPD was found to be higher than the cantilever conventional group. Displacement in X, Y and Z axes was less in cantilever RBFPD.


Subject(s)
Dental Bonding/methods , Models, Dental , Dental Stress Analysis/methods , Denture Design , Denture, Partial, Fixed , Denture, Partial, Fixed, Resin-Bonded , Finite Element Analysis , Glass Ionomer Cements , Humans , Resin Cements , Shear Strength , Tooth Preparation, Prosthodontic
4.
Article in English | IMSEAR | ID: sea-139781

ABSTRACT

Harmonious occlusion is a critical requirement for successful oral rehabilitation. Conventional techniques of construction have been unsuccessful in producing a prosthesis that can be inserted without intraoral occlusal adjustment. This article discusses the use of functionally generated path technique with double casting to fabricate fixed partial dentures. The merits of this approach and the technique involved are discussed in detail.


Subject(s)
Adult , Dental Articulators , Dental Casting Technique , Dental Occlusion , Dental Occlusion, Centric , Denture Design , Denture, Partial, Fixed , Humans , Jaw Relation Record/instrumentation , Jaw Relation Record/methods , Male , Occlusal Adjustment , Surface Properties
5.
Article in English | IMSEAR | ID: sea-139765

ABSTRACT

Objectives: The dual-arch impression technique is convenient in that it makes the required maxillary and mandibular impressions, as well as the inter-occlusal record in one procedure. The accuracy of inter-abutment distance in dies fabricated from dual-arch impression technique remains in question because there is little information available in the literature. Materials and Methods: This study was conducted to evaluate the accuracy of inter-abutment distance in dies obtained from full arch dual-arch trays with those obtained from full arch stock metal trays. Results and Conclusion: The metal dual-arch trays showed better accuracy followed by the plastic dual-arch and stock dentulous trays, respectively, though statistically insignificant. The pouring sequence did not have any effect on the inter-abutment distance statistically, though pouring the non-working side of the dual-arch impression first showed better accuracy.


Subject(s)
Alloys , Bicuspid , Dental Abutments/standards , Dental Articulators , Dental Impression Materials/chemistry , Dental Impression Technique/instrumentation , Dental Impression Technique/standards , Models, Dental/standards , Dental Occlusion, Centric , Denture Design/standards , Denture, Partial, Fixed , Equipment Design , Humans , Jaw Relation Record/instrumentation , Jaw Relation Record/methods , Molar , Plastics , Polyvinyls/chemistry , Siloxanes/chemistry , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL